Recent content by hamd01

  1. H

    Insulated stud wall electrics

    Hi guys. After much advice on these forums, I'm well on with a stud wall in our single skin outbuilding. A couple of images....but I know you guys know what a stud wall looks like :p The battens will have 130mm kingspan between them, with a 30mm breather gap to the wall. On top of the...
  2. H

    Stud Wall - Help Speeding Up

    So I followed your advice, and have had a few more days on the project. Used the metal brackets, and I recon it has made things twice as fast. Thanks again!
  3. H

    Reduce External Door

    Hi guys, Just after some advice regards an outbuilding I'm renovating. Right now the door is quite large, around 1.2m wide. The door and frame are useless and need ripping out. Ideally, and to reduce cost, Id like to reduce the size of the opening, and then buy a more standard (perhaps used)...
  4. H

    Stud Wall - Help Speeding Up

    Yeah it does need fixing, as it isn't fixed at the top (its a vaulted ceiling). The meta brackets should do the trick thats a good shout....ive got some from a previous project so should work well. Thanks again for your help.
  5. H

    Stud Wall - Help Speeding Up

    Thank you much appreciated. That does look like it would save a lot of time. Only problem would be that it would mean I couldn't push the 130 millimeter insulation board in without think of chunk out.
  6. H

    Stud Wall - Help Speeding Up

    Sorry posisbly daft questions.... how would I fit the packers at the end. The packers are drilled and roe plugged into the wall, which I wouldnt then be able to get to.
  7. H

    Stud Wall - Help Speeding Up

    I'm currently building my first stud wall after much advice on these forums. But my god, it's taking me forever! The wall is 100mmx50mm studs, sitting around 150mm from the stone wall, in prep for the insulation going in. The issue im having is how long its taking me. Each vertical stud is...
  8. H

    Internal insulation on back of exterior wall

    If its an old build in a conservation area, it could be that there is no cavity wall....in which case having a cavity behind the insulation/battens would be correct.... although 2cm would be a bit narrow. Also regards thermal bridging, if the frame has been constructed via a top and bottom...
  9. H

    Insulation + Vapur Barrier

    I'm working on converting an old outbuilding into a couple of rooms. 200 year old building with single stone wall, around 40cm thick. After much advice Ive built the stud wall, and have bagged a good deal on some bulk insulation that will do the walls and floor. I was planning on 100mm but...
  10. H

    To Lag Or Not To Lag

    Total run is 20m. They are flow and return clipped to eachother...so just a few cm apart.
  11. H

    To Lag Or Not To Lag

    I'm in the process of securing 22mm flow and return pipes around what is a barn conversion. The pipes are above ground, behind a kingspan insulated slat-wall. Is it best practice to lag the pipes? Cheers guys.
  12. H

    Securing Mains Cable

    I think Im going to go with the wall option.... puerly as it allows me to get that job out of the way before the stud wall. Will bang some insulation tape on the drill so not to go too deep.
  13. H

    Securing Mains Cable

    Thats not a bad idea tbh.
  14. H

    Securing Mains Cable

    Thanks mate. I am a DIYer so doing it in my own time, so Ill have to take the hit on the extra time. Ive ordered some.
  15. H

    Securing Mains Cable

    Thank you.... my tiny brain is struggling to understand how hammering a pin in will cause the plug to expand in the wall, but that looks like a good solution! Will give me 16 year old helper pleanty to be getting on with!
Back